Operation introduction of electrostatic oiler XCTZ-2 controller

  Operation introduction of the XCTZ-2 controller for electrostatic oiler:
  1. Press the "Set" button (which displays the password prompt). After entering the password, press the "Set" button to access the program menu. Use the "+", "-", "Exit", and "Set" buttons to adjust the system parameters for each phase. (For details, please refer to the instruction manual.)
  2. System parameter settings:
  1) Belt speed upper limit - 100-1000M/min
  2) Belt speed lower limit 0005 M/min
  3) Upper limit of oil temperature: 0-360℃
  4) Lower limit of oil temperature: 0320℃
  5) Maximum oil flow rate: 0340ml/min
  6) Operating mode: 0000 for gear speed measurement (automatic fuel injection control). 0002 for constant fuel output (manual fuel injection).
  7) Gear coefficient: Adjusting this system parameter can make it consistent with the belt speed of the skin pass mill.
  8) Speed voltage: Not used.
  9) Oil temperature calibration: 0012
  10) Change Password: Users can modify this password, but they must remember it after changing it.
  11) Starting fuel quantity: 0020
  12) Oil output limit: 350ml/min
  13) Language selection: 0000 for Chinese, 0001 for English.
  14) Pump speed calibration: 108